The BC Biomedical Model SA-2010S Series is a microprocessor-d electrical safety analyzer with a built-in patient simulator. It allows for a multitude of tests to be performed on a device using the same unit and lead connections. It provides a full electrical safety analyzer, as well as ECG Simulation with four waveforms with constant QRS duration and six machine performance testing waveforms. There is Patient Lead testing for 10 inputs. SA-2010S Series Basic Features:
? Led status indicators ? Audio feedback ? Touch control keys – no knobs ? 10 universal patient lead inputs ? High impact plastic case
Safety Analyzer Capabilities:
? Line voltage measurement ? Device under test current measurement ? Earth / ground lead resistance ? Earth / ground leakage current ? Enclosure / chassis leakage current ? External resistance ? External leakage current ? Source receptacle wiring integrity monitor ? True RMS measurements ? AAMI ES1-1993 or IEC 601 selectable test loads ? 90 to 264 VAC operation ? Full 20 amp rating ? Self test points ? Externally replaceable ground fuse ? Automatic load reversal delay ? Patient lead to lead leakage current ? Patient lead to earth / ground leakage current ? Patient isolation leakage current ? External isolation leakage current
Patient Simulator Capabilities:
? Sine: 10, 60 AND 100 HZ ? ECG: 30, 60, 120 AND 240 BPM ? Square: 0.125 AND 2.0 HZ ? Triangle: 2 HZ ? High level output (1 V p-p) ? Amplitude accuracy: +/- 2% ? Frequency accuracy: +/- 0.5% SA-2010S-R: ? RS-232 serial communications
美國(guó)BC SA-2010S醫(yī)用安規(guī)測(cè)試儀基本特征:
? LED狀態(tài)指示燈
? 音頻反饋
? 觸摸控制鍵 - 無(wú)旋鈕
? 10個(gè)通用患者導(dǎo)線輸入
? 高沖擊塑料外殼
SA-2010S安規(guī)測(cè)試儀安全分析儀功能:
? 線路電壓測(cè)量
? 待測(cè)電流測(cè)量設(shè)備
? 接地/接地引線電阻
? 接地/接地漏電流
? 外殼/機(jī)箱漏電流
? 外部電阻
? 外部漏電流
? 源插座接線完整性監(jiān)視器 ?
真有效值測(cè)量
? AAMI ES1-1993或IEC 601可選測(cè)試負(fù)載
? 90至264 VAC運(yùn)行
? 全20安培額定值
? 自檢點(diǎn)
? 外部可更換接地保險(xiǎn)絲
? 自動(dòng)負(fù)載反轉(zhuǎn)延遲
? 患者導(dǎo)致引線漏電流
? 患者導(dǎo)通接地/漏電流
? 患者隔離漏電流
? 外部隔離漏電流
患者模擬器功能: ? 正弦:10,60和100HZ ? 心電圖:30,60,120和240 BPM ? 方形:0.125和2.0 HZ ? 三角形:2 HZ
? 高電平輸出(1 V pp)
? 幅度精度:+/- 2%
? 頻率精度:+/- 0.5%
美國(guó)BC SA-2010S-R安規(guī)測(cè)試儀:
? RS-232串行通信
The BC Biomedical Model SA-2010S Series is a microprocessor-
SA-2010S Series Basic Features:
? Led status indicators
? Audio feedback
? Touch control keys – no knobs
? 10 universal patient lead inputs
? High impact plastic case
Safety Analyzer Capabilities:
? Line voltage measurement
? Device under test current measurement
? Earth / ground lead resistance
? Earth / ground leakage current
? Enclosure / chassis leakage current
? External resistance
? External leakage current
? Source receptacle wiring integrity monitor
? True RMS measurements
? AAMI ES1-1993 or IEC 601 selectable test loads
? 90 to 264 VAC operation
? Full 20 amp rating
? Self test points
? Externally replaceable ground fuse
? Automatic load reversal delay
? Patient lead to lead leakage current
? Patient lead to earth / ground leakage current
? Patient isolation leakage current
? External isolation leakage current
Patient Simulator Capabilities:
? Sine: 10, 60 AND 100 HZ
? ECG: 30, 60, 120 AND 240 BPM
? Square: 0.125 AND 2.0 HZ
? Triangle: 2 HZ
? High level output (1 V p-p)
? Amplitude accuracy: +/- 2%
? Frequency accuracy: +/- 0.5%
SA-2010S-R:
? RS-232 serial communications